Gas analysis

Request payload

{
    "method": "scalechem.gasAnalysis",
    "params": {
        "chemistryModel": "chem",
        "temperature": {
            "value": 30.0,
            "unit": "°C"
        },
        "pressure": {
            "value": 2.0,
            "unit": "atm"
        },
        "inflows": {
            "unit": "mole %",
            "values": {
                "H2O": 10.0,
                "CO2": 10.0,
                "CH4": 40.0,
                "C4H10": 20.0
            }
        },
        "saturateWithH2O": true
    }
}

param

type

description

chemistryModel

string

temperature

pressure

inflows

object

saturateWithH2O

boolean

option to add H2O to saturate the vapor phase.

params.saturateWithH2O input is optional. By default, it's set to false.

In addition to the inputs shown above, some optional properties may also be specified. They can be viewed at Optional Inputs.

Response (status = PROCESSED)

The output of this calculation is the stream output which is common result output for all OLI's flash calculations or an error.

Survey Calculation

Survey calculation is supported for the variables below. Please refer to Survey calculation for explained input schema.

supported params.surveyInputs[{}].field

"/params/temperature/value"

"/params/pressure/value"

"/params/inflows/values/<InflowName>"